Satellit TV 15 B (large heating insert)
The proven heating insert for hot air tiled stoves with 9 and 12 kW heating output. Simply select the desired heating output from the variants of the IHS 2000 B oil evaporation burner.
Technical data Satellit TV 15 B 9 kW
| Type | Satellite TV 15 B with burner IHS 2000 B |
| 9 kW | |
| Energy efficiency class | B |
| Energy efficiency index | EEI 84,98 |
| Nominal heat input full load (kW) | 10 |
| Nominal heat output full load (kW) | 9 |
| Minimum heat output (kW) | 4.1 |
| Partial load (kW) | 4.1 |
| Oil flow full load (ml / min) | 17 |
| Combustion air volume (standard condition) (m³ / h) N | 13.7 |
| Exhaust gas temperature (C °) | 180 |
| Required minimum delivery pressure (hPa) | 0.15 |
| Exhaust flow rate (standard condition) (g/s) N | 5.25 |
| Indirect heating function | No |
| Direct heat output (kW) | 9 |
| Indirect heat output (kW) | 0 |
| Heating oil EL | liquid |
| Space heating emissions Nox (mg / kWhinput (GCV)) |
98.8 |
Technical data Satellit TV 15 B 12 kW
| Type | Satellite TV 15 B with burner IHS 2000 B |
| 12 kW | |
| Energy efficiency class | B |
| Energy efficiency index | EEI 84,24 |
| Nominal heat input full load (kW) | 13.3 |
| Nominal heat output full load (kW) | 12 |
| Minimum heat output (kW) | 5.4 |
| Partial load (kW) | 5.4 |
| Oil flow full load (ml / min) | 22.6 |
| Combustion air volume (standard condition) (m³ / h) N | 18.2 |
| Exhaust gas temperature (C °) | 190 |
| Required minimum delivery pressure (hPa) | 0.15 |
| Exhaust flow rate (standard condition) (g/s) N | 6.98 |
| Indirect heating function | No |
| Direct heat output (kW) | 12 |
| Indirect heat output (kW) | 0 |
| Heating oil EL | liquid |
| Space heating emissions Nox (mg / kWhinput (GCV)) |
111 |
Junior B (small heating insert)
The oil heating insert Junior B impresses with its small and compact design. Among other things, it is ideally suited for the renovation of existing systems in apartments. Often the output of the suitable oil evaporation burner IHS 2000 B of 6 kW is completely sufficient with optimal efficiency.
Technical Data Junior B 6 kW
| Type | Junior B with burner IHS 2000 B |
| 6 kW | |
| Energy efficiency class | B |
| Energy efficiency index | EEI 86,42 |
| Nominal heat input full load (kW) | 6.6 |
| Nominal heat output full load (kW) | 6 |
| Minimum heat output (kW) | 2.7 |
| Partial load (kW) | 2.7 |
| Oil flow full load (ml / min) | 11.2 |
| Combustion air volume (standard condition) (m³ / h) N | 9 |
| Exhaust gas temperature (C °) | 142 |
| Required minimum delivery pressure (hPa) | 0.15 |
| Exhaust flow rate (standard condition) (g/s) N | 3.46 |
| Indirect heating function | No |
| Direct heat output (kW) | 6 |
| Indirect heat output (kW) | 0 |
| Heating oil EL | liquid |
| Space heating emissions Nox (mg / kWhinput (GCV)) |
51.2 |
Oil evaporation burner IHS 2000 B
The IHS 2000 B oil evaporation burner is the heart of the heat generation in combination with the appropriate heating inserts. It ensures almost soot and smoke-free combustion of the heating oil and is therefore almost residue-free.
Room control panel RT 2001
The RT 2001 control panel for controlling the appropriate oil evaporation burner includes functions such as radio clock, digital display, chimney sweep button, setback mode, fault memory, party circuit and much more.